NP2 Specifications |
|
Rear Panel DIP Switch selections |
|
|
|
Relay 1 |
|
Extend –
switch 1 is for extending the detector output after the vehicle has left
the loop. Switch 1 in the OFF position provides no extension. Switch 1
in the ON position provides a 5 second extension once the vehicle leaves
the loop. This extension applies to relay 1 only. |
|
|
|
Delay – switch
2 is for providing a 2 second delay, Detector will ignore the vehicle
until the vehicle has been present over the loop for 2 seconds. Switch 2
in the OFF position provides no delay. Switch 2 in the ON position
provides for the 2-second delay. This delay applies to relay 1 only. |
|
|
|
Presence Time
– switch 3 provides for either a 1 hour presence or permanent presence.
Switch 3 in the OFF position provides for 1 hour of presence. Switch 3 in
the ON position provides for permanent presence. The above presence
settings apply to relay 1 only. (Other options are available). |
|
|
|
Relay 2 |
|
|
|
Pulse Length – switch 4 provides for either a 250mS pulse length or a 500mS pulse length. Switch 4 in the OFF position provides a 250mS (standard) pulse length. Switch 4 in the ON position provides a 500mS pulse length. |
|
|
|
Operating Mode
– switch 5 and switch
6 determine the operating mode for Relay 2. The four modes are as
follows:
|
|
|
|
Switch 5 and switch 6 OFF
provides pulse-on-entry. |
|
Switch 5 ON & switch 6
OFF provides pulse-on-leaving. |
|
Switch 5 OFF & switch 6
ON provides for presence. |
|
Switch 5 and switch 6 ON provides a fault output. |
|
|
| Front
Panel Selections |
|
|
|
Sensitivity –
controlled by front panel rotary switch.
|
|
·
0 = Low
sensitivity |
|
·
9 = High
sensitivity |
|
Medium sensitivity is used for most applications; this is a setting of 4
or 5. Always use the lowest sensitivity setting that detects the desired
vehicles. |
|
|
|
Frequency –
four separate settings controlled by front panel DIP switches.
|
|
·
2+1 = High |
|
·
2+0 =
Medium High |
|
·
1+0 =
Medium Low |
|
·
0+0 = Low |
|
|
| Reset – front panel reset performs a hard reset of the detector. |
|
Factory Settings: |
Sensitivity Boost
– automatic during detect except in the
|
||
|
|
highest sensitivity
setting (9). |
||
|
·
Set to HI
frequency |
|
||
|
·
Set to
Medium sensitivity (5) |
Factory Options: |
||
|
·
Extend/Delay in the OFF position |
Presence lengths of
15, 30, 60 minutes or permanent. |
||
|
·
Presence
time set to 1 hour |
Pulse lengths of 250mS, 500mS, 1, 2 or
4
seconds. |
||
|
·
Pulse
length set to 250msec |
Extend times of
0, 2,
5
or 10 seconds. |
||
|
·
Relay 1 =
fail-safe |
Delay times of
0,
1,
2 or 4
seconds. |
||
|
·
Relay 2 =
fail-secure |
Relay 1
fail-safe
or fail-secure. |
||
|
|
Relay 2 fail-safe or
fail-secure. |
||
|
Relay Output Rating:
7A 277VAC/30VDC. |
Note: Bold /
Italics indicates standard configuration. |
||
|
|
Connector – 11Pin Amphenol | ||
|
Power:
240 VAC, 120 VAC, 24 VAC, 24 VDC or 12 VDC. |
Pin # |
Function |
Color |
|
(70mA DC or
1W AC) |
1 |
Power (+) |
Black |
|
|
2 |
Power (-) |
White |
|
Inductance Range:
20uH to 1500uH. |
3 |
Relay 2 N.O. |
Orange |
|
|
4 |
Ground |
Green |
|
Temperature Range:
-30 F to +180 F.
|
5 |
Relay 1 Com |
Yellow |
|
|
6 |
Relay 1 N.O. |
Blue |
|
Lead-In Length:
up to 2500 ft. with proper lead-in and loop. |
7 |
Loop |
Gray |
|
|
8 |
Loop |
Brown |
|
Mechanical: 1 3/8”w X 3
3/32”h X 3 ½”l. |
9 |
Relay 2 Com |
Red |
|
|
10 |
Relay 1 N.C. |
White/Blk |
|
Weight:
8 oz. |
11 |
Relay 2 N.C. |
White/Red |
|
|
|||
|
Supply Voltage
– incorrect voltage supplied to the unit will
|
Note: The above connection is shown with correct power supplied and no vehicle present. | ||
|
not result in damage, the
unit will simply not operate until
|
|||
| correct voltage is supplied. No fuses need to be reset. | |||
|
|
Northstar Controls L.L.C. warrants this product against defects in manufacturing and workmanship for one year from date of shipment from the Northstar Controls L.L.C. factory. | ||
|
Indicators – front panel
indicators include: |
|||
|
Power – Green,
solid with correct power supplied. |
|||
|
Relay 1 – Red,
solid during detect. |
|||
|
Relay 2 – Red,
solid during detect. |
*Specifications are subject to change without notice. |
||
|
Fault – Yellow,
solid during current fault, flashing for |
|||
|
historical fault. |
L NP2-Rev A |
||
•
|
Model Ordering Information |
|
|
Unit Voltage |
Part # |
|
240
VAC |
NP2-240AC |
|
120
VAC |
NP2-120AC |
|
24
VAC |
NP2-24AC |
| **24 VAC/DC** | **NP2-24AC/DC** |
|
24
VDC |
NP2-24DC |
|
12
VDC |
NP2-12DC |