PDF Version

 

LIS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Index

By Size & Number of Turns  

4 FOOT LOOP WIDTH

Loop Size

(ft)

Inductance

(mh)

Loop Size

(ft)

Inductance

(mh)

Loop Size

 (ft)

Inductance

(mh)

2 Turn

3 Turn

4 Turn

5 Turn

1 Turn

2 Turn

3 Turn

1 Turn

2 Turn

4 x 4

20

44

78

125

4 x 35

35

105

235

4 x 70

67

201

4 x 6

25

56

100

 

4 x 40

39

119

266

4 x 75

71

215

4 x 10

36

81

144

 

4 x 45

44

132

 

4 x 80

76

228

4 x 15

50

112

199

 

4 x 50

49

146

 

4 x 85

81

242

4 x 20

64

143

253

 

4 x 55

53

160

 

4 x 90

85

256

4 x 25

78

174

 

 

4 x 60

58

174

 

4 x 95

90

270

4 x 30

91

204

 

 

4 x 65

62

187

 

4 x 100

94

283

6 FOOT LOOP WIDTH

Loop Size

(ft)

Inductance

(mh)

Loop Size

(ft)

Inductance

(mh)

Loop Size

 (ft)

Inductance

(mh)

1 Turn

2 Turn

3 Turn

4 Turn

1 Turn

2 Turn

3 Turn

1 Turn

2 Turn

6 x 4

8

25

56

100

6 x 35

38

116

259

6 x 70

72

217

6 x 6

10

31

70

124

6 x 40

43

130

 

6 x 75

77

231

6 x 10

14

43

96

171

6 x 45

48

145

 

6 x 80

82

246

6 x 15

19

58

129

229

6 x 50

53

159

 

6 x 85

87

260

6 x 20

24

72

161

286

6 x 55

58

173

 

6 x 90

91

275

6 x 25

29

87

194

 

6 x 60

63

188

 

6 x 95

96

289

6 x 30

34

101

226

 

6 x 65

67

202

 

6 x 100

101

303

Special notes:

1. The optimum operation range is between 70mhand 200mh.

2. All values are calculated using 14ga. wire and a loop having a 20’ twisted lead.

3. Changing the wire gauge will change these values (+ -) 0.02%.
4. Changing the lead length will change these values (+ -) 0.22mh/ft.

 • Home • Ordering • Contact Us • Index Page 1 • Index Page 2 • Index-Page 3 • Reference •