Product Description
Traffic Detector Inductive Loop Sealant
EX = Extra Flexible
Pro-Seal 6006EX is an extra flexible, two-component pourable grade sealant. Specially designed for sealing traffic detector loops in both asphalt and concrete. Pro-Seal 6006EX fully encapsulates the loop wires for added protection. 6006EX is also an excellent sealant for embedding preformed detector loops.
Pro-Seal Advantages
|
- Bonds to both asphalt and concrete.
|
|
- Convenient 1 gallon can package.
|
- Minimum equipment required for application.
|
- Unaffected by salts, auto fluids, gasoline, etc.
|
- Quick cure allows traffic lanes to be opened faster, with no pick-up or tacking.
|
- Other packaging available (5 gallon & 55 gallon drums).
|
Mixing
1. Remove lid and add the required amount of catalyst (Hardener). Remember to use less catalyst in the summer and more catalyst in the winter.
2. Mix for 30-45 seconds using a variable speed drill equipped with a mixing attachment. If mixing by hand, use a paint stir stick or other suitable device and mix for a minimum of three minutes.
Application Instructions:
1. Pour “mixed” Pro-Seal 6006 into loop slot, encapsulating loop wires.
2. Scrape any excess sealant off roadway with a squeegee. Curing: The amount of catalyst (hardener) used can be varied for a faster or slower cure. Consult Technical Data Sheet DLS-1 for cure times.
Packaging:
Pro-Seal 6006 is packaged in convenient 1 gallon cans, 5 gallon pails, and 55 gallon drums for use with pneumatic pump systems
Storage: Shelf life is one year in original unopened containers. Do not store above 100°F.
Specifications
Color: |
Brown |
Viscosity: |
4800 cps (maximum) |
Weight Per Gallon: |
12.0 lb/gal (minimum) |
Specific Gravity: |
1.33-1.38 |
Catalyst Required: |
MEKP (Red) 2 tubes/gallon |
Catalyzation Ratio: |
1% |
Gel Time @ (77°F): |
13.0 to 18.0 Min.-ASTM C881 |
Shore “D” Hardness |
@ 60 Min. 15-20 @ 24 hours 45-50 |
Elongation: |
30% (min)-ASTM D638 |
Tensile Strength: |
500 psi (max)-ASTM D638 |
Adhesion to Concrete: |
300 PSI-ASTM D3163-84 |
Adhesion to Asphalt: |
Excellent |
Water Absorption: |
0.18%-ASTM D570 |
Oil Absorption (No.3 Oil): |
0.02%-ASTM D570 |
Gas Absorption: |
0.04%-ASTM D570 |
This product can only be shipped via ground transport.
DLS-1 Technical Data Sheet
For Pro-Seal 6006 & 6006EX
The proportion of catalyst to sealer is not very critical in obtaining a complete cure. The quantity of catalyst can be adjusted depending on climatic conditions. Use less catalyst in hot weather and more catalyst in cold weather. Each gallon of Pro-Seal is supplied with two (2) 1 ounce tubes of catalyst. Extra catalyst can be purchased separately. Use the chart below to determine the amount of catalyst to use.
Curing Time Matrix
N/R=Not Recommended Ambient Temperature in °F |
Tube(s) |
30°- 45° |
45°- 55° |
55°- 65° |
65°- 75° |
75°- 80° |
80°- 90° |
+90° |
Per Gallon |
Time in Minuets |
1 |
N/R |
N/R |
N/R |
N/R |
N/R |
N/R |
12-18 |
2 |
N/R |
30-35 |
25-30 |
20-25 |
15-20 |
10-15 |
Under 10 |
3 |
20-25 |
15-20 |
10-15 |
7-10 |
N/R |
N/R |
N/R |
Note: To thicken Pro-Seal for use on steep inclines dry sand may be added during the mixing process. Dry sand may be spread on top of Pro-Seal to make it instantly tack free. Sand is especially helpful for lead-ins across open lanes of traffic.
Use the coverage chart below to calculate the fill rate per gallon of Pro-Seal in various size saw cuts slots.
6006 Sealer Fill Matrix
Saw Cut |
Width |
Depth |
3/16″ |
1/4″ |
5/16″ |
3/8″ |
1/2″ |
1″ |
100′ |
80′ |
66′ |
53′ |
40′ |
1 1/2″ |
75′ |
53′ |
45′ |
36′ |
27′ |
2″ |
50′ |
40′ |
33′ |
26′ |
20′ |
3″ |
36′ |
27′ |
23′ |
18′ |
14′ |