Single Channel-Dual Relay Inductive Loop Vehicle Detector

The NP2 inductive loop detector has been specifically designed and engineered for use in the Parking & Access Control industries. With standard operations including programmable pulse and presence options, fail-safe or fail-secure operation, compatibility with all radio controls, timing features and more, the NP2 covers your detection needs.

Product Description

Model NP2 Features:

· 10 selectable Sensitivities

· 4 selectable Frequencies

· Wrong voltage protection

· Output Timing – Extend & Delay

· Selectable Presence times

· Selectable Pulse lengths

· Automatic Sensitivity Boost

· Separate Power, Detect and Fault Indicators

· Available in: 240VAC, 120VAC, 24VAC, 24VDC or 12VDC & 24V AC/DC.
The NP2 inductive loop detector has been specifically designed and engineered for use in the Parking & Access Control industries. With standard operations including programmable pulse and presence options, fail-safe or fail-secure operation, compatibility with all radio controls, timing features and more, the NP2 covers your detection needs.

This loop detector’s wide inductance range allows for use with small loops sometimes found in the Parking/Access Control industries (for recommended loop sizes please consult the LIS Reference Section).

Separate indicators for power on, detect relay 1, detect relay 2 and fault, provide for quick visual verification of proper operation. Loop diagnostics are easily viewed with the front panel fault indicator, differentiating between current and historical faults thus facilitating troubleshooting.

Small size and full list of features lend the NP2 to any Parking or Access Control use from simple presence detection to configured pulse/presence lengths with output extensions and/or delays.

Reliable operation and long field life are key engineering goals in every NorthStar product.

 

 

NP2 Specifications

Rear Panel DIP Switch selections

Relay 1

Extend – switch 1 is for extending the detector output after the vehicle has left the loop. Switch 1 in the OFF position provides no extension. Switch 1 in the ON position provides a 5 second extension once the vehicle leaves the loop. This extension applies to relay 1 only.

Delay – switch 2 is for providing a 2 second delay, Detector will ignore the vehicle until the vehicle has been present over the loop for 2 seconds. Switch 2 in the OFF position provides no delay. Switch 2 in the ON position provides for the 2-second delay. This delay applies to relay 1 only.

Presence Time – switch 3 provides for either a 1 hour presence or permanent presence. Switch 3 in the OFF position provides for 1 hour of presence. Switch 3 in the ON position provides for permanent presence. The above presence settings apply to relay 1 only. (Other options are available).

Relay 2

Pulse Length – switch 4 provides for either a 250mS pulse length or a 500mS pulse length. Switch 4 in the OFF position provides a 250mS (standard) pulse length. Switch 4 in the ON position provides a 500mS pulse length.

Operating Mode – switch 5 and switch 6 determine the operating mode for Relay 2. The four modes are as follows:

Switch 5 and switch 6 OFF provides pulse-on-entry.

Switch 5 ON & switch 6 OFF provides pulse-on-leaving.

Switch 5 OFF & switch 6 ON provides for presence.

Switch 5 and switch 6 ON provides a fault output.

Front Panel Selections

Sensitivity – controlled by front panel rotary switch.

· 0 = Low sensitivity

· 9 = High sensitivity

Medium sensitivity is used for most applications; this is a setting of 4 or 5. Always use the lowest sensitivity setting that detects the desired vehicles.

Frequency – four separate settings controlled by front panel DIP switches.

· 2+1 = High

· 2+0 = Medium High

· 1+0 = Medium Low

· 0+0 = Low

Reset – front panel reset performs a hard reset of the detector.

Factory Settings:

Set to HI frequency
Set to Medium sensitivity (5)
Extend/Delay in the OFF position
Presence time set to 1 hour
Pulse length set to 250msec
Relay 1 = fail-safe
Relay 2 = fail-secure
Relay Output Rating: 7A 277VAC/30VDC.

Power: 240 VAC, 120 VAC, 24 VAC, 24 VDC or 12 VDC. (70mA DC or 1W AC).

Inductance Range: 20uH to 1500uH.

Temperature Range: -30 F to +180 F.

Lead-In Length: up to 2500 ft. with proper lead-in and loop.

Mechanical: 1 3/8”w X 3 3/32”h X 3 ½”l.

Weight: 8 oz.

Supply Voltage – incorrect voltage supplied to the unit will not result in damage, the unit will simply not operate until correct voltage is supplied. No fuses need to be reset.

Indicators – front panel indicators include:

Power – Green, solid with correct power supplied.

Relay 1 – Red, solid during detect.

Relay 2 – Red, solid during detect.

Fault – Yellow, solid during current fault, flashing for historical fault.

Sensitivity Boost – automatic during detect except in the highest sensitivity setting (9).

Factory Options:

Presence lengths of 15, 30, 60 minutes or permanent.

Pulse lengths of 250mS, 500mS, 1, 2 or 4 seconds.
Extend times of 0, 2, 5 or 10 seconds.
Delay times of 0, 1, 2 or 4 seconds.
Relay 1 fail-safe or fail-secure.
Relay 2 fail-safe or fail-secure.
Note: Bold / Italics indicates standard configuration.

Pin # Function Color
1 Power (+) Black
2 Power (-) White
3 Relay 2 N.O. Orange
4 Ground Green
5 Relay 1 Com Yellow
6 Relay 1 N.O. Blue
7 Loop Gray
8 Loop Brown
9 Relay 2 Com Red
10 Relay 1 N.C. White/BLK
11 Relay 2 N.C. White/Red

Note: The above connection is shown with correct power supplied and no vehicle present.

Northstar Controls L.L.C. warrants this product against defects in manufacturing and workmanship for one year from date of shipment from the Northstar Controls L.L.C. factory.

*Specifications are subject to change without notice.

 

NP2